WOOD GASIFYINGBOILERATTACK DPX STANDARD, PROFI, LAMBDAATTACK, s.r.o. - aktualizácia 05/2010SKENDERUFRESRO

Pagina 2

10 ATTACK DPX LAMBDA 1. – Green control light 2. – Yellow Green control light 3. – Red Green control light 4. - Display 5. – Button „+“ 6. – Button

Pagina 3

11 Purpose of usage Ecological warmwater boiler Ecological warmwater boiler Attack DPX is designed for heating of dwelling houses and similar objec

Pagina 4 - Manual content:

12 damaged. Creation of tar and condensate in the feed hopper is a phenomenon accompanying wood gasifying. If the boiler was out of order for a longer

Pagina 5 - Introduction:

13 of wood rises, output is lower than demanded and the service life of boiler as well as that of flue is shortened. If the draft is as specified,

Pagina 6 - Technical parameters:

14 thermostat. In case the temperature in the boiler does not exceed 65 °C in 2 hours of burning up time, the regulator stops the flue gas ventilato

Pagina 7

15 Boiler overheating If the temperature of the boiler raises to more than 105 °C, the regulator stops the flue-gas fan and the control light of

Pagina 8 - Instrument panel

16 Technical description of the ATTACK DPX LAMBDA: Combustion regulation The boiler output is regulated by means of the exhaust temperature – to the

Pagina 9 - ATTACK DPX PROFI

17 Functions and text display at heating-up or refuel After pressing the button “+” (see button 5 in chap. 1.3), starts the process that includes foll

Pagina 10 - ATTACK DPX LAMBDA

18 Temperature reaches 299°C and less, the exhaust fan is switched on again. This is protection against exhaust fan and/or the exhaust sensor damage.

Pagina 11 - Attention

19 Menu Submenu Indication Boiler set to °C -- Shows adjusted temperature of water in boiler. Boiler temperature °C

Pagina 12

2 ATTACK DPX - Wood gasifying boiler - Assembly, control heat up and attendance training is perfomed by field engineer trained by pr

Pagina 13

20 Settings for the commission of the ATTACK DPX LAMBDA . The start-up of device is enabled, when the minimum requirements for test- or heating opera

Pagina 14 - Fuel shortage

21 a difference between flue gas temperature and temperature in the boilers 06 : Disconnection O2

Pagina 15 - Error messages

22 Cancelling of the manufacturer´s function This process requires code of manufacturer. It is possible to set operation hours of the boiler, to re

Pagina 16 - Combustion regulation

23 Selection Submenu Svítí Information Scale of O2 End of the test (+,-) After pressing the „+“ button, „calibrate“ appears on dipslay. Calib

Pagina 17

24 automatically. During this test, it is necessary to hold the + button within 30 seconds, to prevent automatic stop of the test (see explanation in

Pagina 18

25 remove the packing cord from the rabbet by a screwdriver. Remove the nozzle body and clean the holder thoroughly from the tar and old lute. Put the

Pagina 19 - Setting

26 is guaranteed for maximum moisture content of 20%. Guarantee expires at boiler operation with cut wood with humidity over 20%. Energy content of

Pagina 20

27 space of min. 1meter. This space is necessary for basic operation, maintenance and service of the boiler. Location of the boiler in the dwelling sp

Pagina 21

28 Boiler connection to the electricity mains The boiler is connected to the mains of 230 V/50 Hz by a supply cord and plug. The voltage is of M type

Pagina 22

29 Regumat consists from three way mixing valve, circuitingpump, closing valve, thermometers and isolation. This solution is advantegeus because its c

Pagina 23

3 - the mixing device Regumat ATTACK-OVENTROP is not installed in the system to ensure temperature of return water into boiler at least a

Pagina 24

30 Obligate norms for projecting and assembly of boilers: STN EN 303-5 Solid fuel boilers for heating STN 73 42 10 Manufacturing of chimneys and f

Pagina 25

31 Installation and exchange of fireproof adapting pieces Put the rear part into the lower chamber, the intagliated part backwards. It is necessary

Pagina 26

32 Connection schemes Scheme of connection with regulation system REGUMAT ATTACK-OVENTROPBOILERATTACKExpansion tankPumpRegumatATTACK--OVENTROPHeatin

Pagina 27 - ATTENTION!

33 Connection with heat accumulators Connection system is based on principle of heating up of water in accumulation tanks, where the warmth is gradu

Pagina 28 - Boiler protection against

34 Advantages Boiler installation with accumulation tank brings several advantages: - lower fuel consumption (up to 30%). Boiler works at full output

Pagina 29

35 Liquidate the packaging by repurchase / collection of raw materials, respectively use regulated dumping ground. Accessories The ATTACK DPX bo

Pagina 30

36 Possible faults and methods of their deletion Fault Cause Solution Control light „Net“ does not lighti No voltage in mains Incorrectly plugged

Pagina 31

37 Errors and warnings with the ATTACK DPX LAMBDA system By following errors and warnings it is not possible to burn in the boiler: - red display 3 l

Pagina 32 - Connection schemes

38 Too high flue gas temperature (warning) Cause: Control light 3 red: Flue gas temperature > 300°C Flickers Temperature of flue gas is too high B

Pagina 33

39 Antifreeze protection (warning) Cause: Control light 2 yellow: Correction: Reset: Boiler temperature is < 7°C, when the boiler is switched off

Pagina 34 - Liquidation of packaging

4 Manual content: 2. Important 4. Content 5. Introduction, general description 6. Technical parameters 7. Boiler dimensions 8,9, 10. Instrument

Pagina 35 - Accessories

40 off by the flue gas sensor temperature decreases for 25% within 15 minutes, the boiler is switched off. The STB is started Residual warmth of

Pagina 36

41 Table of dependence of resistance on temperature of the thermal probe of heating water (Profi version) Temperature °C MIN Resistance kOhm MAX

Pagina 37

42 Electrical schemes of connection of the ATTACK DPX STANDARD, PROFI, LAMBDA boilers

Pagina 39

44 ATTACK DPX LAMBDA Connection to the network from the bottom side of regulator FUSESENSORNETWORKPROTECTION CONDUCTORBOILERSWITCHING CONTACTWITHOU

Pagina 40

45 Oxygene probe (Lambda sonda) 4-conductor silicone-covered flexicord with conductor´s crossection of 0,75mm2 white = warming 12Vblack= + signal of p

Pagina 41

46 Elektric voltage 230V Grounding of covering Network cordPhaseGroundingZero conductorNetwork breaker max. 10A3-conductor flexicord 1,

Pagina 42

47 ORIGINAL ES DECLARATION OF CONFORMITY NR. POZ-003/110110 Producer: Rudolf Bakala, corporate representative of the company DIELENSKÁ KRUŽNÁ 5020

Pagina 43

48 European directives: 2004/108/ES, 2006/95/ES, 2006/42/ES Certificates: E-30-01097-09 z 30.11.2009 E-30-01096-09 z 30.11.2009 Last to digits of the

Pagina 44

49 Notes

Pagina 45 - Probe warming

5 Introduction: Dear customer, thank you for confidence that you showed us by purchasing our product - the ATTACK wood gasifying boiler. We wish yo

Pagina 47

51 Tel: 00421 43 4003 101Fax: 00421 43 4003 106E-mail: [email protected] [email protected]: www.attack.skATTACK, s.r.o.Dielen

Pagina 48

6 Technical parameters: Boiler type DPX15 DPX25 DPX30 DPX35 DPX40 DPX45 Boiler output kW 15 25 30 35 40 45 Surface of exchanger m² 1,98

Pagina 49

7 Dimensions of the ATTACK DPX boilers DPX15 DPX25 DPX30 DPX35 DPX40 DPX45 C.H. flow connection – „E“ G6/4“ G6/4“ G6/4“ G6/4“ G2“ G2“ C.H

Pagina 50

8 Instrument panel ATTACK DPX STANDARD The wood gasifying boiler "ATTACK DPX Standard" is controled by boiler and flue gas thermostat.

Pagina 51 - Producer:

9 ATTACK DPX PROFI The ATTACK DPX Profi version in comparison with Standard version represents higher attendance comfort, possibility of output modu